AutomataNexus

NexusEdge

Version 1.0.2

Next-Generation Edge Computing Platform for Building Management Systems with AI-Powered Fault Detection

NexusEdge V1.0.2 combines edge computing, artificial intelligence, and industrial-grade hardware control into a unified platform. Transform traditional building management systems into intelligent, self-optimizing environments.

Key Differentiators

What sets NexusEdge apart from traditional BMS solutions

26 TOPS AI Processing

On-device neural network inference via Hailo-8 NPU

8 Specialized Neural Models

Purpose-built AI for HVAC fault detection and diagnostics

Real-Time Edge Control

Sub-second response times with local processing

Human-in-the-Loop AI Safety

MFA-protected AI action approval system

20 Managed Microservices

Robust PM2-orchestrated service architecture

Legacy Protocol Bridge

BACnet MS/TP and Modbus RTU/ASCII integration

Target Markets

Industries that benefit from NexusEdge deployment

Commercial

Office, retail, education

Industrial

Manufacturing, warehouses

Healthcare

Hospitals, clinics, pharma

Hospitality

Hotels, resorts, venues

Agricultural

Greenhouses, vertical farms

Platform Benefits

Measurable improvements for your facility

Energy Optimization

AI-driven setpoint optimization reduces energy consumption by up to 30%

Predictive Maintenance

Neural network analysis detects equipment anomalies before failures

Operational Visibility

Real-time dashboards with trend analysis and audit logging

Secure Remote Access

Cloudflare tunnel with JWT authentication and MFA

Interface Screenshots

Click any image to view full size with pan & zoom

Login / Landing Page

Login / Landing Page

Secure authentication portal

Hailo-8 NPU Neural Models

8 purpose-built neural networks running at 26 TOPS performance

APOLLO

Master Coordinator & Cost Predictor

Params: 20.8MAcc: 99.92%

AQUILO

Electrical Fault Detection

Params: 608KAcc: 96.7%

BOREAS

Refrigeration Diagnostics

Params: 1.2MAcc: 91.91%

COLOSSUS

Multi-Model Integration

Params: 17.3MAcc: 100%

GAIA

Environmental & Air Quality

Params: 1.8MAcc: 94.2%

NAIAD

Hydronic & Water Systems

Params: 1.1MAcc: 93.5%

VULCAN

Heating & Combustion

Params: 1.5MAcc: 95.8%

ZEPHYRUS

Ventilation & Airflow

Params: 1.4MAcc: 94.7%

System Architecture

Robust microservices and modern technology stack

20 PM2-Managed Microservices

Core Services (4)

Portal (8000), API (3001), Controller, Coordinator

Monitoring (5)

Alarm Monitor, BMS Monitor, BMS Reporter, Processing Reporter, Safety Watchdog

Supporting (5)

Audit, Email, Weather, Terminal (8002), DB Cache Manager

Plugins (6)

OpenZL Cache, LegacyComms, AI Providers, AI Response Bridge, NexusForge, Ollama

Technology Stack

FrontendReact 18 + TypeScript, Chart.js, Socket.IO
BackendNode.js 20, Express.js, Socket.IO, SQLite, PM2
AI/MLHailo-8 NPU, HailoRT, Custom .hef Models, Ollama
ProtocolsBACnet MS/TP, Modbus RTU/ASCII, I2C, SPI, UART
Databasesmetrics.db, alarms.db, audit.db, weather.db

Equipment Control System

Comprehensive control for 9+ equipment types

Equipment TypeExecutorControl Capabilities
Air Handling UnitsairHandlerExecutor.jsSupply/Return fans, dampers, heating/cooling valves, VFD control
Boiler PlantsboilerExecutor.jsLead/lag staging, OAT reset, injection valve PID, pump sequencing
Steam BundlessteamBundleExecutor.jsSteam valve modulation, condensate control, preheat sequences
ChillerschillerExecutor.jsChilled water staging, condenser control, refrigerant monitoring
Cooling TowerscoolingTowerExecutor.jsFan staging, basin heating, water treatment integration
DOAS UnitsdoasExecutor.jsDedicated outdoor air, energy recovery, demand ventilation
VAV BoxesvavExecutor.jsZone control, reheat valves, occupancy-based optimization
Pumping SystemspumpExecutor.jsVFD control, lead/lag, differential pressure, amp monitoring
GreenhousesgreenhouseExecutor.jsClimate control, irrigation, lighting, CO2 enrichment

Built-in Safety Protections

Multiple layers of equipment and building protection

Freezestat Protection

Automatic freeze protection valve actuation with manual reset

Safety Watchdog

Independent monitor sets safe defaults if coordinator fails

Proof-of-Flow

Equipment interlocks based on pump amp verification

High/Low Limits

Temperature and pressure safety shutdowns

OAT Lockouts

Heating/cooling enable based on outdoor conditions

Pump Amp Latching

Grace periods prevent false shutdowns

Technical Specifications

Hardware and software requirements

Software

OSRPi OS 64-bit
Node.jsv20.x LTS
Python3.11+
DatabaseSQLite 3.x
HailoRT4.x+

Hardware

CPURPi 5 @ 2.4GHz
RAM8GB
Storage256GB+ NVMe
NPUHailo-8 (26 TOPS)
NetworkGigabit Ethernet

Network Ports

Web Portal:8000
API:3001
Terminal:8002
NexusForge:5001
Ollama:11434

Bring AI to the Edge